BXGTT - DTR REDUCERS, DTR 600
- MSDS: BXGTT
- Manufacturer: PPG INDUSTRIES INC
- Product Name: DTR REDUCERS, DTR 600
- National Stock Number: 8010-00N059369
Product Identification
Product ID:DTR REDUCERS, DTR 600
MSDS Date:05/24/1993
FSC:8010
NIIN:00N059369
MSDS Number: BXGTT
Responsible Party
ALLISON PARK, PA 15101
US
Emergency Phone: 304-843-1300
Info Phone: 412-492-5555; 216-572-6111
Cage: 47695
Contractor
Telephone: 1-800-245-2974 (CAL HYPO)
Cage: 47695
Ingredients
ACETONE (SARA 313) (CERCLA)
CAS: 67-64-1
RTECS: AL3150000
Fraction By Weight: 35-40%
OSHA PEL 1000 PPM
ACGIH TLV: 750 PPM;1000 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
VM & P NAPHTHA; (LIGHT ALIPHATIC SOLVENT NAPHTHA)
CAS: 64742-89-8
Fraction By Weight: 45-50%
OSHA PEL N/K
ACGIH TLV: N/K
XYLENE (SARA 313) (CERCLA)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 5-10%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA 313) (CERCLA)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 25-30%
OSHA PEL 200 PPM
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
HEAVY AROMATIC NAPHTHA (SOLVENT NAPHTHA); (HEAVY AROMATIC
CAS: 64742-94-5
RTECS: WF3100000
Fraction By Weight: 30-35%
OSHA PEL N/K
ACGIH TLV: N/K
SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (LIGHT
CAS: 64742-95-6
RTECS: WF3400000
Fraction By Weight: 30-35%
OSHA PEL N/K
ACGIH TLV: N/K
PROPIONIC ACID, 2-METHYL-, MONOESTER W/2,2,4-TRIMETHYL-1,
CAS: 25265-77-4
RTECS: UF6000000
Fraction By Weight: 2-5%
OSHA PEL N/K
ACGIH TLV: N/K
ACETIC ACID, BUTYL ESTER; (N-BUTYL ACETATE) (CERCLA)
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 10-15%
OSHA PEL 150 PPM
ACGIH TLV: 150 PPM;200 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
HEALTH PROFESSIONALS CONCERNING LATEST HAZARD
RTECS: 9999999ZZ
TO DETERMINE TYPE OF AIRBORNE CONTAMS AGAINST
RTECS: 9999999ZZ
BELOW STATED LIMIT, AS APPROPRIATE.
RTECS: 9999999ZZ
& FULL LENGTH FACESHIELD .
RTECS: 9999999ZZ
Fire Fighting
Flash Point Method:PMCC
Flash Point:-4F,-20C
Lower Limits:1%
Extinguishing Media:USE NFPA CLASS B EXTINGS (CARBON DIOXIDE, DRY
CHEM/UNIVERSAL AQ FILM FORMING FOAM) DESIGNED TO EXTING NFPA
CLASS(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. WATER SPRAY MAY BE USED TO COOL CLSD
CNTNRS TO PVNT PRESS BUILD-UP & POSS(SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAMES. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. DO NOT APPLY ON HOT (SUPDAT)
Exposure Controls
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:>136F,>58C
Vapor Pres:139.5
Vapor Density:HVR/AIR
Spec Gravity:0.7-1
Appearance and Odor:NON-VISCOUS LIQUID W/ODOR CHARACTERISTIC OF
SOLVENTS LISTED IN INGS.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG ALKALIS, STRONG MINERAL ACIDS OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.